|
|||
Validating an xCAT Installation for Use with Moab
Introduction to Validating xCAT ConfigurationThis document describes a series of steps to validate xCAT configuration prior to configuring Moab to manage hardware via xCAT. It is assumed the reader is familiar with xCAT and the xCAT configuration on the target site. This document does not provide xCAT configuration documentation or troubleshooting information; please refer to the xCAT documentation for such information. Verifying Node ListVerify that all nodes that Moab will manage are known to xCAT with the xCAT nodels command. Ensure that all expected (and no unexpected) nodes are listed. You may find it useful to create new group names to identify Moab managed nodes.
Reporting Node StatusVerify that all nodes report their status correctly using the xCAT nodestat command. Ensure that all nodes show the correct status (sshd, installing, noping, and so forth); there should not be any timeouts or error messages.
Verifying Hardware Management ConfigurationVerify that all nodes that Moab will manage have hardware management interfaces correctly configured using the xCAT nodels and rpower commands. After each of the rpower commands, verify the requested state was achieved with rpower stat.
Verifying Provisioning ImagesVerify that all operating system images that Moab uses are configured correctly in xCAT. For stateful images, test that all combinations of operating system, architecture, and profile install correctly.
For stateless images, test that nodes are able to network boot the images.
Verifying VM MigrationIf you use VM migration, verify that xCAT can successfully perform migrations using the rmigrate command.
See Also
Searches Moab documentation only
|
|||
| © 2001-2010 Adaptive Computing Enterprises, Inc. | |||