Establishing Script Interaction between Moab and a Power Management Tool
18.1 Establishing Script Interaction between Moab and a Power Management Tool
On the same node on which Moab is running, there must be a command for Moab to call to switch power on or off. The command is usually a script that interacts with your preferred power management tool. Moab calls the script as follows:
<Script Name> <Node Name/List> <ON|OFF>
> /opt/moab/tools/node.power.pl node002 ON
<Node List> is a comma delimited list of nodes. To power off multiple nodes, try:
> /opt/moab/tools/node.power.pl node002,node003,node004 OFF
To enable script interaction between Moab and your preferred power management tool, configure the NODEPOWERURL parameter on a per-resource manager basis.
RMCFG[prov] TYPE=NATIVE RESOURCETYPE=PROV
RMCFG[prov] NODEPOWERURL=exec://$HOME/tools/prov/node.power.pl
RMCFG[prov] CLUSTERQUERYURL=exec://$HOME/tools/prov/cluster.query.pl
The scipt's purpose is to provide Moab information about whether power to nodes is on or off; such information is relayed for each node with a POWER value of either "on" or "off." The actual state of nodes is internally tracked by Moab. When Moab powers off a node, it is still eligible to run jobs, so even though it is powered off, its state is idle. Thus, this script must report a STATE of "Unknown" to prevent Moab from considering the node unavailable. When a node is powered off outside of a Moab action (such as a node failure), then Moab recognizes the state being reported from its resource manager as down (rendering it unavailable). To prevent Moab from considering a node unavailable, as previously mentioned, the STATE must be reported as "Unknown." The following is sample output for cluster.query.pl:
x01 POWER=on STATE=Unknown
x02 POWER=off STATE=Unknown
x03 POWER=off STATE=Unknown
x04 POWER=off STATE=Unknown
x05 POWER=off STATE=Unknown
See Also